MIL-STD-1553B Aerospace Data Bus Cable

MIL-STD-1553B aerospace data bus cable is designed for reliable multiplex signal transmission in aerospace, defense, marine, weapon systems, and harsh-environment electronic equipment. Built with stranded silver-plated copper alloy conductors, X-ETFE insulation and jacket, and single or double braided shielding options, it supports 77±5Ω characteristic impedance, 600V continuous operating voltage, and -65°C to +200°C service conditions.

MIL-STD-1553B Data Bus
77±5Ω Impedance
X-ETFE Insulation
Single / Double Shielded

Overview

MIL-STD-1553B Aerospace Data Bus Cable is designed for deterministic and reliable multiplex signal transmission in aerospace, defense, marine, weapon systems, and other harsh-environment electronic equipment.

This 1553B data bus cable uses stranded silver-plated copper alloy conductors, X-ETFE insulation, braided shielding, X-ETFE jacket, and filler construction to support stable electrical performance under demanding operating conditions. It is designed to meet the performance requirements of MIL-STD-1553B data bus applications, providing reliable signal transmission where impedance stability, shielding effectiveness, mechanical toughness, and environmental resistance are critical.

This page is intended for product selection. Exact specifications should be confirmed by selected construction type, shielding layer, shielding material, drawing, project standard, and application environment before ordering.

Series Options

The table below helps buyers understand the main construction options for this 1553B aerospace data bus cable before reviewing detailed drawings or datasheets.

Series Option Product Positioning Typical Selection Scenario
HYTC / 1553B Single-layer braided shield 1553B data bus cable For MIL-STD-1553B data bus applications requiring compact construction, stable impedance, and single-layer tinned copper or silver-plated copper braided shielding.
HYTS / 1553B Double-layer braided shield 1553B data bus cable For harsher EMI environments or higher shielding requirements where double-layer tinned copper or silver-plated copper braided shielding is preferred.
BYC Custom Custom 1553B data bus cable construction For projects requiring custom shielding material, jacket color, marking, documentation, testing, or compliance support based on drawings or specifications.

Features

MIL-STD-1553B Data Bus Performance

Designed for 1553B data bus signal transmission where deterministic communication, stable impedance, and reliable multiplex transmission are required.

77±5Ω Characteristic Impedance

Supports 77±5Ω characteristic impedance at 1MHz for MIL-STD-1553B data bus cable applications.

X-ETFE Insulation and Jacket

X-ETFE insulation and jacket provide high and low temperature resistance, aging resistance, radiation resistance, corrosion resistance, flame resistance, and mechanical toughness.

Single or Double Braided Shielding

HYTC supports single-layer braided shielding, while HYTS supports double-layer braided shielding for stronger EMI protection and lower transfer impedance.

Harsh-Environment Reliability

Suitable for aerospace, defense, weapon systems, marine equipment, and severe operating environments requiring high cable reliability.

Custom Project Support

BYC Cables can review drawings, shielding requirements, marking, jacket color, testing, and documentation needs based on project specifications.

Construction & Materials

This 1553B data bus cable is built with conductor, insulation, shielding, jacket, and filler construction. Final selection should be based on shielding layer, shielding material, signal integrity requirements, installation environment, and project documentation needs.

Construction Options

Component Available Options Selection Notes
Conductor Stranded silver-plated copper alloy conductor Designed for reliable electrical performance and demanding aerospace signal transmission applications.
Insulation X-ETFE insulation Provides electrical insulation, temperature resistance, radiation resistance, aging resistance, and mechanical toughness.
Shielding Single-layer or double-layer braided shield Single-layer shielding is used for compact 1553B cable constructions; double-layer shielding is used where stronger EMI protection and lower transfer impedance are required.
Shield Material Tinned copper wire braid or silver-plated copper wire braid Shield material can be selected according to corrosion resistance, conductivity, project standard, and environmental requirement.
Jacket X-ETFE jacket Provides protection against harsh environments, mechanical stress, heat aging, radiation, corrosion, and flame exposure.
Filler Filler construction Supports cable geometry, roundness, mechanical stability, and controlled transmission characteristics.
Marking & Documentation Custom marking and documentation support available Can support project identification, traceability, datasheets, test requirements, and specification review.

Construction Differences

Type Shielding Structure Confirmed Information When to Choose
HYTC / 1553B Single-layer braided shield Available with single-layer tinned copper wire braided shield or single-layer silver-plated copper wire braided shield. Representative outside diameter is 3.30±0.15 mm, with maximum weight of 24 g/m. Choose HYTC when a compact single-shielded 1553B data bus cable is suitable for the project environment.
HYTS / 1553B Double-layer braided shield Available with double-layer tinned copper wire braided shield or double-layer silver-plated copper wire braided shield. Representative outside diameter is 3.70±0.15 mm, with maximum weight of 24 g/m. Choose HYTS when stronger shielding effectiveness, lower transfer impedance, or harsher EMI environment requirements are expected.
BYC Custom Custom 1553B cable construction Shielding material, marking, jacket color, testing, datasheet, and compliance documentation can be reviewed based on project requirements. Choose BYC Custom when the standard HYTC or HYTS construction does not fully match your drawing, specification, installation condition, or procurement requirement.

Specifications

The specifications below are intended for preliminary product selection. Final values should be confirmed according to selected construction type, shielding layer, shielding material, drawing, and project standard.

Product Family MIL-STD-1553B Aerospace Data Bus Cable
Application Standard Designed to meet the performance requirements of MIL-STD-1553B data bus applications
Reference Product Standard Q/HY106-2010. This should be treated as a reference product standard, not a third-party certification.
Conductor Stranded silver-plated copper alloy conductor
Insulation X-ETFE insulation
Jacket X-ETFE jacket
Shielding Options Single-layer or double-layer braided shielding with tinned copper wire or silver-plated copper wire options
Rated Operating Temperature -65°C to +200°C
Maximum Applicable Frequency 30MHz
Minimum Bending Radius 20mm
Continuous Operating Voltage 600V
Insulation Resistance ≥1500 MΩ·km
Conductor DC Resistance at 20°C ≤109 Ω/km
Voltage Withstand Core-to-core and core-to-shield: 2500V / 5min, no breakdown
Core-to-Core Capacitance at 1MHz ≤98 pF/m
Characteristic Impedance at 1MHz 77±5Ω
Attenuation at 1MHz ≤4.6 dB / 100m
Velocity of Propagation 61%
Transfer Impedance at 30MHz Single-layer shield: ≤0.1 Ω/m. Double-layer shield: ≤0.01 Ω/m.
Customization Available based on drawings, samples, technical specifications, or project documentation requirements

For accurate quotation, please provide the target shielding type, shielding material, required impedance, jacket color, marking, operating environment, testing requirement, and applicable drawings or specifications.

Representative Size and Weight

Type Outside Diameter Maximum Weight
HYTC / 1553B, HYTC / 1553B-2 3.30±0.15 mm 24 g/m
HYTS / 1553B, HYTS / 1553B-2 3.70±0.15 mm 24 g/m

Representative Mechanical and Electrical Performance

Performance Item Confirmed / Representative Value Notes
Tensile Strength Insulation and jacket tensile strength ≥34.5 N/mm² Representative mechanical performance value.
Elongation at Break Insulation ≥75%; jacket ≥50% Applies to insulation and jacket material performance.
Low-Temperature Bend -65°C ±2°C / 4h, no cracking, immersion voltage withstand test passes Supports low-temperature aerospace and defense wiring applications.
Crosslinking Verification 300°C ±3°C / 7h, no cracking, immersion voltage withstand test passes Representative verification for X-ETFE construction.
Continuous Operating Voltage 600V For rated data bus cable operation.
Characteristic Impedance 77±5Ω at 1MHz Critical parameter for MIL-STD-1553B data bus signal transmission.
Transfer Impedance ≤0.1 Ω/m for single-layer shield; ≤0.01 Ω/m for double-layer shield at 30MHz Double-layer shielding provides lower transfer impedance.

Applications

MIL-STD-1553B aerospace data bus cable is suitable for systems that require reliable multiplex data transmission, stable impedance, strong shielding performance, and long-term service in severe operating environments.

Aerospace Data Bus Systems

For aircraft and spacecraft data bus wiring where MIL-STD-1553B signal transmission performance is required.

Defense & Weapon Systems

For defense electronics and weapon systems requiring reliable multiplex signal transmission and harsh-environment cable performance.

Marine & Shipboard Electronics

For shipboard systems and marine electronic equipment requiring shielded data bus cable performance in demanding environments.

Harsh-Environment Control Systems

For electronic control systems, avionics, instruments, and mission-critical equipment requiring stable communication cable performance.

Selection Guide

Use this guide as a starting point. Final selection should be confirmed by shielding layer, shielding material, impedance requirement, installation space, EMI environment, and project documentation requirements.

Requirement Recommended Type Selection Reason
Compact 1553B data bus wiring HYTC / 1553B Single-layer braided shielding provides a compact construction for standard MIL-STD-1553B data bus cable applications.
Higher shielding performance HYTS / 1553B Double-layer braided shielding provides lower transfer impedance and better shielding performance for harsher EMI environments.
Tinned copper shield preference Tinned Shield Can be selected according to cost, corrosion resistance, and project specification requirements.
Silver-plated copper shield preference Silver-Plated Shield Can be selected when higher conductivity, oxidation resistance, or specific project requirements call for silver-plated shielding.
Custom marking or documentation BYC Custom BYC Cables can review drawings, datasheets, test requirements, marking, color, and documentation needs.

Customization Options

BYC Cables can support custom MIL-STD-1553B aerospace data bus cable requirements based on drawings, samples, technical specifications, or project documentation needs.

Shielding Layer

Single-layer or double-layer braided shielding can be selected based on EMI environment, transfer impedance, and installation requirements.

Shielding Material

Tinned copper or silver-plated copper braided shielding can be reviewed according to conductivity, corrosion resistance, and project specification.

Jacket & Marking

X-ETFE jacket color, printing, identification marking, and traceability requirements can be reviewed for project documentation.

Electrical Performance

Characteristic impedance, capacitance, attenuation, transfer impedance, and voltage withstand requirements can be confirmed by datasheet or test plan.

Testing Support

Performance testing, technical confirmation, and inspection documentation can be reviewed based on customer and project requirements.

Technical Review

BYC Cables can review drawings, samples, system requirements, and application conditions before recommending a suitable construction.

Request a Quote

Please provide the required shielding type, shielding material, impedance requirement, jacket color, marking, operating environment, testing requirement, and applicable drawings or specifications.

FAQ

What is MIL-STD-1553B data bus cable used for?

It is used for deterministic multiplex data transmission in aerospace, defense, marine, weapon systems, avionics, and harsh-environment electronic equipment where reliable communication and stable electrical performance are required.

What is the characteristic impedance of this 1553B cable?

The representative characteristic impedance is 77±5Ω at 1MHz, which is a key parameter for MIL-STD-1553B data bus cable applications.

What is the difference between HYTC and HYTS types?

HYTC uses single-layer braided shielding, while HYTS uses double-layer braided shielding. HYTS provides lower transfer impedance and is better suited for harsher EMI environments.

What shielding materials are available?

Available shielding options include tinned copper wire braided shield and silver-plated copper wire braided shield, depending on the selected construction and project requirement.

What is the operating temperature range?

The rated operating temperature range is -65°C to +200°C, making the cable suitable for demanding aerospace and defense environments.

Can BYC Cables customize 1553B data bus cable?

Yes. BYC Cables can review custom requirements for shielding layer, shielding material, jacket color, marking, testing, datasheets, and documentation based on drawings or project specifications.

contact us

STEP 1

Inquiry Received

STEP 2

Technical Review

STEP 3

24H Response​