Marine Watertight and Deep-Water Sealed Cables
Marine watertight and deep-water sealed cables are designed for ships, submarines, underwater devices, transducers, offshore platforms, and marine electrical systems requiring water blocking, pressure resistance, seawater corrosion resistance, and reliable power, control, communication, RF, or signal transmission. This product family includes general marine watertight cables and JSHF / JSHFP deep-water sealed cables for 300m and 450m underwater applications, with LSZH sheath, shielded options, multi-core constructions, and custom project support.
300m / 450m Deep-Water Use
LSZH Sheath Options
Power / Control / Signal
Overview
Marine Watertight and Deep-Water Sealed Cables are designed for ships, submarines, underwater devices, transducers, offshore platforms, and marine electrical systems that require water blocking, pressure resistance, seawater corrosion resistance, and long-term transmission reliability.
This product family combines general marine watertight cable constructions with JSHF / JSHFP deep-water sealed rubber-sheathed cable options. It supports power transmission, control circuits, communication wiring, RF transmission, signal transmission, and integrated marine cable assemblies where water ingress protection and reliable operation under underwater or shipboard conditions are critical.
This page is intended for product selection. Exact specifications should be confirmed by cable type, water-pressure requirement, underwater depth, core count, conductor cross-section, shielding, sheath material, insulation system, transmission function, and project standard before ordering.
Series Options
The table below helps buyers understand the main marine watertight and deep-water sealed cable options before reviewing drawings, datasheets, or project specifications.
| Series Option | Product Positioning | Typical Selection Scenario |
|---|---|---|
| SM Watertight Cable | RF watertight cable | For shipboard or underwater RF transmission where water pressure resistance, seawater corrosion resistance, and stable signal transmission are required. |
| ZM Watertight Cable | Integrated watertight cable | For combined power, control, signal, or communication transmission where multiple functions need to be integrated into one watertight cable. |
| JK Watertight Cable | Shipboard control watertight cable | For marine control systems requiring watertight construction, pressure resistance, and reliable electrical performance. |
| JH Watertight Cable | Shipboard communication watertight cable | For shipboard communication systems requiring watertight sealing and stable signal transmission in marine environments. |
| JSHF / JSHFP-30 | Deep-water sealed marine cable for 300m underwater use | For ships, submarines, underwater vehicles, transducers, and offshore equipment requiring longitudinal water-blocking and underwater use down to 300m. |
| JSHF / JSHFP-45 | Deep-water sealed marine cable for 450m underwater use | For deeper underwater applications requiring sealed rubber-sheathed cable construction and reliable transmission down to 450m. |
| BYC Custom | Custom watertight or deep-water sealed cable construction | For projects requiring custom power, control, RF, communication, signal, core count, cross-section, shielding, sheath, water pressure, or documentation support. |
Features
Marine Watertight Construction
Designed to help prevent water from migrating through damaged cable sections into shipboard or underwater electrical equipment.
Deep-Water Sealed Options
JSHF / JSHFP-30 and JSHF / JSHFP-45 options support 300m and 450m underwater use for demanding marine and subsea applications.
Pressure and Seawater Resistance
Representative constructions support water-pressure requirements such as 4.5MPa, 6.0MPa, and 10.0MPa depending on selected model.
Power, Control, Communication and RF
Available constructions can support electrical power, control circuits, communication lines, RF transmission, signal wiring, or integrated cable functions.
LSZH Sheath Options
Low-smoke halogen-free sheath material can be selected based on shipboard, underwater, and offshore cable requirements.
Custom Marine Cable Support
BYC Cables can review drawings, water-pressure ratings, core counts, shielding, sheath materials, and test requirements for custom marine cable projects.
Construction & Materials
Marine watertight and deep-water sealed cables can be configured for power, control, RF, communication, and signal transmission. Final construction should be selected according to water depth, pressure rating, electrical performance, shielding requirement, sheath material, installation environment, and project standards.
Construction Options
| Component | Available Options | Selection Notes |
|---|---|---|
| Transmission Function | Power, control, RF, communication, signal, or integrated transmission | Function selection determines conductor design, shielding, insulation, sheath, and testing requirements. |
| Conductor | Selected according to model, cross-section, and electrical performance requirement | Conductor structure and resistance should be confirmed by selected cable model or project drawing. |
| Insulation | Fluoroplastic, polyethylene, XLPE, EP rubber, or project-specified insulation options depending on cable type | Insulation material should be selected according to voltage withstand, flexibility, temperature, and marine environment requirements. |
| Shielding | Unshielded or shielded constructions available depending on series | Shielding is recommended when signal stability, EMI protection, or communication performance is required. |
| Sheath | Low-smoke halogen-free sheath, chlorosulfonated polyethylene, polyurethane, or project-specified sheath options | Sheath selection should consider seawater corrosion, abrasion, pressure, flexibility, and shipboard safety requirements. |
| Water Blocking | Watertight or longitudinal water-sealed constructions | Helps reduce water migration through the cable when the sheath is damaged or exposed to pressure. |
| Core Count | Deep-water sealed cable options support 1–61 cores depending on conductor cross-section | Core count should be selected according to power, control, signal, or integrated system requirements. |
| Customization | Custom water pressure, depth rating, sheath, shielding, conductor size, marking, and documentation support | BYC Cables can review special project requirements before recommending a suitable construction. |
Construction Differences
| Cable Type | Construction Focus | Confirmed Information | When to Choose |
|---|---|---|---|
| General Marine Watertight Cable | Watertight cable for shipboard and underwater electrical or signal transmission | Includes SM RF watertight cable, ZM integrated watertight cable, JK shipboard control watertight cable, and JH shipboard communication watertight cable options. Representative constructions may support water pressure such as 4.5MPa, 6.0MPa, or 10.0MPa depending on model. | Choose when the project requires watertight performance, seawater corrosion resistance, abrasion resistance, and reliable transmission for shipboard or underwater devices. |
| JSHF / JSHFP-30 | Deep-water sealed rubber-sheathed cable for 300m underwater use | Designed for longitudinal watertight sealing in shipboard, submarine, underwater vehicle, transducer, offshore transducer, and offshore platform applications. | Choose when the cable needs to support deep-water use down to 300m and reliable power, lighting, control, or signal transmission. |
| JSHF / JSHFP-45 | Deep-water sealed rubber-sheathed cable for 450m underwater use | Designed for deeper underwater applications requiring longitudinal water sealing and robust marine cable construction. | Choose when the cable needs to support underwater use down to 450m or higher deep-water sealing requirements. |
| BYC Custom | Custom marine watertight or deep-water sealed cable construction | Water pressure, underwater depth, core count, conductor size, shielding, sheath material, cable function, and documentation can be reviewed by project requirement. | Choose when standard watertight or JSHF / JSHFP constructions do not fully match your drawing, equipment, water depth, or operating environment. |
Specifications
The specifications below are intended for preliminary product selection. Final values should be confirmed according to selected model, water pressure, underwater depth, conductor cross-section, core count, sheath material, and project standard.
| Product Family | Marine Watertight and Deep-Water Sealed Cables |
|---|---|
| Included Cable Types | SM RF watertight cable, ZM integrated watertight cable, JK shipboard control watertight cable, JH shipboard communication watertight cable, JSHF / JSHFP deep-water sealed cable |
| Main Applications | Ships, submarines, underwater devices, deep-sea vehicles, shipboard transducers, offshore transducers, offshore oil platforms, and marine electrical systems |
| Transmission Functions | Power, lighting, control, communication, RF, signal, or integrated transmission depending on selected construction |
| Underwater Use | JSHF / JSHFP-30 for 300m underwater use; JSHF / JSHFP-45 for 450m underwater use |
| Representative Water Pressure | Representative values may include 4.5MPa, 6.0MPa, and 10.0MPa depending on selected model. 4.5MPa is approximately 653psi; 6.0MPa is approximately 870psi; 10.0MPa is approximately 1450psi. |
| Voltage Withstand | Varies by selected model. Representative values include 0.5kV, 1.0kV, 1.5kV, 2.0kV, 2.5kV, and 10.0kV AC. |
| JSHF / JSHFP Rated Voltage | 600V AC |
| JSHF / JSHFP Core Count | 1–61 cores depending on conductor cross-section |
| JSHF / JSHFP Cross-Section Range | (1–61) × 0.5–1.0mm², (1–24) × 1.5–2.5mm², (1–7) × 4.0–6.0mm², and (1–3) × 10.0mm² |
| JSHF / JSHFP Voltage Test | 2.5kV / 5min, no breakdown |
| JSHF / JSHFP Insulation Resistance | ≥150 MΩ·km |
| JSHF / JSHFP Long-Term Operating Temperature | 85°C (185°F) |
| Representative Operating Temperature | Operating temperature varies by selected construction. Representative ranges include -45°C to +85°C (-49°F to +185°F), -45°C to +100°C (-49°F to +212°F), and -40°C to +70°C (-40°F to +158°F). |
| Low-Temperature Bend Test | JSHF / JSHFP: -20±2°C (-4±3.6°F), no cracking |
| Sheath Material | Low-smoke halogen-free sheath material can be selected based on shipboard and underwater cable requirements |
| Flame Retardancy | JSHF / JSHFP flame retardancy can be tested according to GB/T18380-2008 requirements |
| Reference Standards | Reference standards may include GJB774-1989, GJB1916-1994, IEC60092-350:2001, and MIL-DTL-24643C:2009 depending on selected cable type. These should be treated as reference standards, not third-party certifications. |
| Customization | Available based on drawings, samples, technical specifications, water-depth requirements, pressure requirements, or customer-required compliance needs |
For accurate quotation, please provide the required cable function, underwater depth, water-pressure rating, core count, conductor cross-section, shielding requirement, sheath material, operating environment, and applicable drawings or standards.
Representative Watertight Cable Data
| Model | Cable OD | Voltage Withstand | Insulation Resistance | DC Resistance | Water Pressure |
|---|---|---|---|---|---|
| SMYJ-50-5-5 | 22.5±0.3mm | 6.5kV AC | ≥5000 MΩ·km | ≤13.5 Ω/km | Longitudinal and transverse pressure-resistant construction |
| SMYJ-50-9 | 12.5±0.3mm | 12.0kV AC | ≥5000 MΩ·km | ≤3.8 Ω/km | Representative marine watertight construction |
| ZMYP-7 | 15.0±0.3mm | 2.0kV AC | ≥1000 MΩ·km | ≤12.8 Ω/km | Representative integrated watertight cable |
| ZMFJP-13 | 20.0±0.3mm | 1.0kV AC | ≥1000 MΩ·km | ≤35.5 / 20.0 Ω/km | Representative signal / integrated cable construction |
| JHYJP-13×0.34 | 25.0±0.5mm | 1.0kV AC | ≥500 MΩ·km | ≤58.0 Ω/km | Longitudinal 6.0MPa representative construction |
| JKFHP-8×2.0 | 18.0±0.5mm | 1.0kV AC | ≥200 MΩ·km | ≤13.0 Ω/km | Representative shipboard watertight construction |
JSHF / JSHFP Mechanical Performance
| Performance Item | Representative Value | Notes |
|---|---|---|
| Finished Cable Voltage Test | 2.5kV / 5min, no breakdown | Applies to JSHF / JSHFP deep-water sealed cable. |
| Insulation Resistance | ≥150 MΩ·km | Final value should be confirmed by selected construction. |
| Insulation Elongation at Break | ≥250% | Representative insulation mechanical performance. |
| Insulation Tensile Strength | ≥4.83MPa | Applies to listed insulation material performance. |
| Sheath Elongation at Break | ≥250% | Representative sheath mechanical performance. |
| Sheath Tensile Strength | >10.0MPa | Applies to listed sheath material performance. |
| Low-Temperature Bend | -20±2°C (-4±3.6°F), no cracking | Supports marine installation and low-temperature operation review. |
| Minimum Bending Radius | Shielded cable: 6D. Non-shielded cable: 4D when D≤25mm; 6D when D>25mm. | D refers to cable outside diameter. |
Applications
Marine watertight and deep-water sealed cables are suitable for shipboard, underwater, and offshore systems that require reliable electrical, signal, RF, communication, or control transmission under water pressure and corrosive marine conditions.
Ships and Submarines
For shipboard power, lighting, control, communication, and signal circuits requiring watertight sealing and marine-grade reliability.
Underwater Devices
For underwater equipment and systems where pressure resistance, water blocking, and seawater corrosion resistance are required.
Deep-Sea Vehicles
For deep-water vehicles and related systems requiring sealed cable construction for 300m or 450m underwater use.
Marine Transducers
For shipboard transducers, offshore transducers, and related marine signal or power transmission applications.
Offshore Platforms
For offshore oil platforms and marine infrastructure requiring durable watertight cable connections.
Integrated Marine Systems
For custom marine cable assemblies combining power, control, communication, RF, or signal transmission in one cable.
Selection Guide
Use this guide as a starting point. Final selection should be confirmed by cable function, underwater depth, water pressure, conductor cross-section, core count, shielding, sheath material, and project standard.
| Requirement | Recommended Type | Selection Reason |
|---|---|---|
| RF transmission with watertight performance | SM | SM series is positioned for RF watertight cable applications requiring stable transmission and marine sealing. |
| Integrated power, control, or signal transmission | ZM | ZM integrated watertight cable is suitable when multiple transmission functions need to be combined. |
| Shipboard control circuits | JK | JK shipboard control watertight cable supports marine control system wiring. |
| Shipboard communication circuits | JH | JH shipboard communication watertight cable supports marine communication cable applications. |
| 300m underwater sealed cable | JSHF / JSHFP-30 | Recommended for deep-water sealed cable applications requiring 300m underwater use. |
| 450m underwater sealed cable | JSHF / JSHFP-45 | Recommended for deeper underwater sealed cable applications requiring 450m underwater use. |
| Custom water pressure or cable function | BYC Custom | BYC Cables can review custom water pressure, depth, core count, shielding, sheath, and transmission requirements. |
Customization Options
BYC Cables can support custom marine watertight and deep-water sealed cable requirements based on drawings, samples, technical specifications, underwater conditions, and project documentation needs.
Transmission Function
Power, lighting, control, communication, RF, signal, or integrated cable functions can be reviewed according to system requirements.
Water Pressure and Depth
Custom water-pressure ratings and underwater depth requirements can be reviewed for shipboard, subsea, and offshore applications.
Core Count and Cross-Section
Multi-core constructions and conductor cross-section can be selected according to power, control, and signal transmission needs.
Shielding
Shielded or unshielded constructions can be reviewed according to EMI protection, signal stability, and marine installation requirements.
Sheath and Insulation
LSZH sheath, polyurethane, chlorosulfonated polyethylene, fluoroplastic, polyethylene, XLPE, EP rubber, or project-specific material systems can be reviewed.
Testing and Documentation
Voltage withstand, insulation resistance, flame retardancy, water pressure testing, datasheets, and inspection documents can be reviewed based on project needs.
Request a Quote
Please provide the required cable function, underwater depth, water-pressure rating, core count, conductor cross-section, shielding requirement, sheath material, operating environment, and applicable drawings or specifications.
FAQ
What are marine watertight cables used for?
They are used for shipboard, underwater, and offshore electrical systems requiring water blocking, seawater corrosion resistance, pressure resistance, and reliable power, control, communication, RF, or signal transmission.
What is the difference between watertight cable and deep-water sealed cable?
General watertight cables focus on preventing water migration and supporting marine transmission functions. Deep-water sealed cables such as JSHF / JSHFP-30 and JSHF / JSHFP-45 are designed for 300m or 450m underwater use.
What do JSHF / JSHFP-30 and JSHF / JSHFP-45 mean?
JSHF / JSHFP-30 refers to deep-water sealed marine cable for 300m underwater use. JSHF / JSHFP-45 refers to deep-water sealed marine cable for 450m underwater use.
Can these cables be used for power and signal transmission?
Yes. Depending on selected construction, these cables can support power, lighting, control, communication, RF, signal, or integrated transmission functions.
What operating temperature ranges are available?
Operating temperature varies by selected construction. Representative ranges include -45°C to +85°C (-49°F to +185°F), -45°C to +100°C (-49°F to +212°F), and -40°C to +70°C (-40°F to +158°F). JSHF / JSHFP long-term operating temperature is 85°C (185°F).
Can BYC Cables customize marine watertight cables?
Yes. BYC Cables can review custom requirements for underwater depth, water pressure, core count, conductor size, shielding, sheath material, transmission function, testing, and documentation.
contact us
STEP 1
Inquiry Received
-
Instant acknowledgment and
dedicated specialist assignment.
STEP 2
Technical Review
-
Expert evaluation of specifications
for optimal reliability.
STEP 3
24H Response
-
Comprehensive proposal and
competitive pricing within 24 hours.
