Fiberglass Braided Silicone Rubber High Temperature Wire
Fiberglass braided silicone rubber high temperature wire is designed for appliances, motors, lighting fixtures, heaters, industrial equipment, and internal wiring applications requiring heat resistance, flexibility, abrasion protection, and mechanical reinforcement. This series includes UL3071, UL3304, and JGP options with silicone rubber insulation, fiberglass braid protection, flexible copper conductor constructions, and voltage-rated options for different high-temperature wiring requirements.
Silicone Rubber Insulation
High Temperature Wire
UL3071 / UL3304 / JGP
Overview
Fiberglass Braided Silicone Rubber High Temperature Wire is designed for appliances, motors, lighting fixtures, heaters, industrial equipment, and internal wiring applications requiring heat resistance, flexibility, abrasion protection, and mechanical reinforcement.
This product family includes UL3071, UL3304, and JGP fiberglass braided silicone wire options. Compared with ordinary silicone rubber insulated wire, fiberglass braided silicone wire adds an external braided layer to improve mechanical protection, abrasion resistance, surface durability, and handling performance in high-temperature wiring environments.
This page is intended for product selection. Exact specifications should be confirmed by selected model, rated voltage, conductor size, conductor material, insulation thickness, braid structure, finished outside diameter, temperature rating, color, and project drawing before ordering.
Series Options
The table below helps buyers compare the main fiberglass braided silicone rubber high temperature wire options before reviewing detailed datasheets or drawings.
| Series Option | Product Positioning | Typical Selection Scenario |
|---|---|---|
| UL3071 | Silicone rubber insulated fiberglass braided wire | For appliances, lighting fixtures, electronic equipment, and temperature sensor lead connections requiring silicone insulation and fiberglass braid protection. |
| UL3304 | High-temperature high-voltage fiberglass braided silicone wire | For burner ignition systems, fuel ignition systems, and high-temperature high-voltage lead wiring requiring fiberglass braid reinforcement. |
| JGP | Fiberglass braided silicone rubber motor lead wire | For AC motor lead wiring and high-temperature motor winding lead connections requiring silicone insulation and braided protection. |
| BYC Custom | Custom fiberglass braided silicone wire | For projects requiring custom conductor size, voltage rating, insulation thickness, braid thickness, outer diameter, color, marking, or documentation support. |
Features
Silicone Rubber Insulation
Silicone rubber insulation provides flexibility, heat resistance, and stable electrical insulation performance for high-temperature wiring environments.
Fiberglass Braided Protection
Fiberglass braid adds mechanical protection, abrasion resistance, and surface reinforcement compared with standard silicone insulated wire.
High Temperature Performance
Selected options are designed for high-temperature equipment wiring, motor lead wiring, lighting, heating equipment, and ignition-related applications.
Voltage-Rated Options
Available options include 600V AC, 10kV AC, and higher-voltage JGP configurations depending on selected model and construction.
Motor and Equipment Wiring
JGP series supports motor winding lead wire applications where silicone insulation and braided mechanical protection are required.
Custom Specification Support
BYC Cables can review conductor size, voltage rating, insulation thickness, braid structure, color, marking, packaging, and documentation requirements.
Construction & Materials
Fiberglass braided silicone rubber wire should be selected according to voltage rating, operating temperature, conductor size, conductor material, insulation thickness, braid protection, flexibility, routing space, and equipment environment.
Construction Options
| Component | Available Options | Selection Notes |
|---|---|---|
| Conductor | Tinned copper wire, nickel-plated copper wire, bare copper, or model-specific copper conductor options | Conductor selection should consider temperature exposure, oxidation resistance, flexibility, solderability, and terminal processing. |
| Insulation | Silicone rubber | Silicone rubber provides flexibility, high temperature resistance, and stable insulation performance in demanding wiring environments. |
| Braid / Reinforcement | Fiberglass braid | Fiberglass braid improves abrasion protection, mechanical reinforcement, and handling durability around heat sources or moving equipment. |
| Rated Voltage | Model-specific voltage ratings including 600V AC, 10kV AC, and JGP high-voltage options | Voltage rating must match equipment design, insulation thickness, braid structure, and applicable project requirements. |
| Temperature Range | Representative listed options include -60°C to +180°C (-76°F to +356°F) and -60°C to +200°C (-76°F to +392°F), depending on selected series. | Temperature rating should be selected according to motor class, heat source exposure, equipment location, and safety margin. |
| Color | White, blue, red, black, brown, yellow, green, yellow/green, or custom colors depending on selected model | Color identification supports circuit management, production assembly, inspection, installation, and maintenance. |
| Customization | Custom conductor size, insulation thickness, braid thickness, voltage, color, marking, packaging, and documentation | BYC Cables can review drawings, samples, equipment requirements, and documentation needs before recommending a final construction. |
Construction Differences
| Series | Construction Focus | Representative Listed Information | When to Choose |
|---|---|---|---|
| UL3071 | Silicone rubber insulated fiberglass braided wire | Listed with 600V AC rating, -60°C to +200°C (-76°F to +392°F) temperature range, silicone insulation, fiberglass braid, and tinned or nickel-plated copper conductor options. | Choose for appliances, lighting, electronic equipment, temperature sensors, and high-temperature internal wiring requiring braided protection. |
| UL3304 | High-temperature high-voltage fiberglass braided silicone wire | Listed with 10kV AC rating, -60°C to +200°C (-76°F to +392°F) temperature range, silicone insulation, fiberglass braid, and tinned or nickel-plated copper conductor options. | Choose for burner ignition systems, fuel ignition systems, and high-voltage lead wiring requiring braided silicone construction. |
| JGP | Fiberglass braided silicone rubber motor lead wire | Listed for AC motor applications with silicone insulation, fiberglass braid, and voltage options including 1140V, 6000V, 10000V, and 13800V. | Choose for AC motors and motor winding lead wire applications requiring braided silicone protection. |
| BYC Custom | Project-specific fiberglass braided silicone wire | Conductor size, voltage rating, insulation thickness, braid thickness, finished outside diameter, color, marking, and documentation can be reviewed. | Choose when standard model data does not fully match your equipment, voltage requirement, motor design, or production process. |
Specifications
The specifications below are intended for preliminary product selection. Final values should be confirmed according to selected model, rated voltage, conductor size, insulation thickness, braid structure, finished outside diameter, temperature rating, and project drawing.
| Product Family | Fiberglass Braided Silicone Rubber High Temperature Wire |
|---|---|
| Included Models | UL3071, UL3304, JGP |
| Insulation Material | Silicone rubber |
| Braid / Reinforcement | Fiberglass braid |
| Conductor Options | Tinned copper wire, nickel-plated copper wire, bare copper, or model-specific copper conductor options |
| Rated Voltage | Model-specific. Representative listed options include 600V AC, 10kV AC, 1140V, 6000V, 10000V, and 13800V depending on selected series. |
| Temperature Range | Representative listed options include -60°C to +180°C (-76°F to +356°F) and -60°C to +200°C (-76°F to +392°F), depending on selected model. |
| Typical Applications | Appliances, lighting fixtures, electronic equipment, temperature sensors, ignition systems, fuel burners, AC motors, and high-temperature internal wiring |
| Wire Size | Available conductor size range varies by selected model and voltage rating. |
| Finished Outside Diameter | Varies by conductor size, insulation thickness, braid thickness, voltage rating, and selected model. |
| Color Options | White, blue, red, black, brown, yellow, green, yellow/green, or custom colors depending on selected model and order requirements |
| Customization | Available based on conductor size, conductor material, voltage rating, insulation thickness, braid thickness, color, marking, packaging, and documentation requirements. |
For accurate quotation, please provide the target model, rated voltage, conductor size, conductor material, temperature requirement, insulation thickness, braid requirement, finished outside diameter limit, color, cable length, and applicable drawings or specifications.
Representative Series Comparison
| Series | Representative Voltage Positioning | Temperature Positioning | Typical Application Note |
|---|---|---|---|
| UL3071 | 600V AC listed option | -60°C to +200°C (-76°F to +392°F) | Appliances, lighting, electronic equipment, temperature sensors, and high-temperature internal wiring. |
| UL3304 | 10kV AC listed option | -60°C to +200°C (-76°F to +392°F) | Burner ignition systems, fuel ignition systems, and high-voltage high-temperature lead wiring. |
| JGP | 1140V, 6000V, 10000V, and 13800V listed options | -60°C to +180°C (-76°F to +356°F) | AC motor lead wiring and motor winding lead connections requiring fiberglass braided silicone protection. |
Applications
Fiberglass braided silicone rubber wires are suitable for electrical systems where heat resistance, flexibility, abrasion protection, mechanical reinforcement, and long-term wiring reliability are important.
Appliances and Lighting
For home appliances, lighting fixtures, electronic equipment, and high-temperature internal wiring requiring braided protection.
Temperature Sensors
For temperature sensor lead wires and sensor connection applications requiring silicone insulation and fiberglass braid reinforcement.
Ignition Systems
For burner ignition systems, fuel ignition systems, and high-voltage lead connections exposed to heat.
AC Motors
For AC motor winding lead connections and motor cable systems requiring silicone insulation and fiberglass braided protection.
Industrial Equipment
For industrial machines, heaters, control equipment, and systems requiring high-temperature reinforced wire.
Custom High-Temperature Wiring
For projects requiring custom conductor size, voltage rating, braid thickness, color, cutting, or documentation support.
Selection Guide
Use this guide as a starting point. Final selection should be confirmed by voltage rating, operating temperature, conductor size, braid requirement, routing space, mechanical protection, and equipment standard.
| Requirement | Recommended Option | Selection Reason |
|---|---|---|
| General high-temperature braided wire | UL3071 | Recommended for appliances, lighting, sensors, and electronic equipment requiring 600V AC fiberglass braided silicone wire. |
| Ignition or burner high-voltage wiring | UL3304 | UL3304 is listed with 10kV AC rating for ignition and burner lead wire applications requiring braided silicone construction. |
| AC motor lead wire | JGP | JGP is designed for AC motor winding lead wire applications with silicone insulation and fiberglass braided protection. |
| Higher-voltage motor wiring | JGP High-Voltage Options | JGP provides listed voltage options including 6000V, 10000V, and 13800V for selected motor lead requirements. |
| Custom braid or size requirement | BYC Custom | BYC Cables can review conductor size, voltage rating, insulation thickness, braid thickness, finished outside diameter, color, and documentation requirements. |
Customization Options
BYC Cables can support custom fiberglass braided silicone rubber wire requirements based on drawings, samples, electrical requirements, operating environment, motor requirements, and project documentation needs.
Voltage Rating
Voltage-rated constructions can be reviewed according to appliance, ignition, motor, industrial equipment, and project requirements.
Conductor Size
Conductor size can be selected according to current load, voltage drop, routing space, termination method, and equipment design.
Insulation and Braid
Silicone insulation thickness, fiberglass braid thickness, and finished outside diameter can be reviewed according to voltage and mechanical protection needs.
Conductor Material
Tinned copper, nickel-plated copper, bare copper, or model-specific conductor options can be reviewed according to temperature and termination requirements.
Color and Marking
Custom colors, stripe marking, printing, and identification requirements can support production, installation, inspection, and maintenance.
Testing and Documentation
Datasheets, inspection records, electrical test data, packaging labels, and project documentation can be provided based on requirements.
Request a Quote
Please provide the target model, rated voltage, conductor size, conductor material, temperature requirement, insulation thickness, braid requirement, finished outside diameter limit, color, cable length, and applicable drawings or specifications.
FAQ
What is fiberglass braided silicone rubber wire used for?
It is used for appliances, lighting fixtures, temperature sensors, ignition systems, AC motors, industrial equipment, and internal wiring requiring heat resistance, flexibility, and abrasion protection.
Which models are included in this series?
This series includes UL3071, UL3304, and JGP fiberglass braided silicone rubber wire options.
What does fiberglass braid add to silicone wire?
Fiberglass braid adds mechanical protection, abrasion resistance, surface reinforcement, and improved handling durability compared with standard silicone insulated wire.
Which option is suitable for ignition systems?
UL3304 is suitable for burner ignition systems, fuel ignition systems, and high-voltage high-temperature lead wire applications.
Which option is suitable for motor lead wiring?
JGP is designed for AC motor lead wiring and motor winding lead connections requiring silicone insulation and fiberglass braided protection.
Can BYC Cables customize fiberglass braided silicone wire?
Yes. BYC Cables can review custom conductor size, voltage rating, insulation thickness, braid thickness, finished outside diameter, color, marking, packaging, and documentation requirements.
contact us
STEP 1
Inquiry Received
-
Instant acknowledgment and
dedicated specialist assignment.
STEP 2
Technical Review
-
Expert evaluation of specifications
for optimal reliability.
STEP 3
24H Response
-
Comprehensive proposal and
competitive pricing within 24 hours.