General Product Overview
| Feature | Specification |
| Product Model | 113L/50 |
| Part Number | YZ113L/50 |
| Insulation Material | FEP (Fluorinated Ethylene Propylene) |
| Jacket Material | FEP (Fluorinated Ethylene Propylene) |
| Maximum Operating Voltage | 1000 Volts |
| Operating Temperature Range | -55 degrees Celsius to +125 degrees Celsius (-67 degrees Fahrenheit to +257 degrees Fahrenheit) |
| Minimum Bending Radius (Static) | 4.0 Millimeters |
| Optimal Preservation Period | Two Months |
| Standard Packing Mode | Paper Plate (1000 Meters per Plate) |
Precision Construction Details
| Layer Component | Material Specification | Construction Design (n/mm) | Diameter (mm) |
| 1. Inner Conductor | Silver-plated Copper Wire | 7 x 0.083 | 0.249 plus or minus 0.02 |
| 2. Insulation Layer | FEP (Fluorinated Ethylene Propylene) – Transparent | Not Applicable | 0.735 plus or minus 0.03 |
| 3. Shielding Layer 1 (Tape) | Copper-Plastic Composite Tape (100 percent Coverage) | 0.012 x 2.5 | 0.759 plus or minus 0.03 |
| 4. Shielding Layer 2 (Braid) | Tinned Copper Wire (90 plus or minus 5 percent Coverage) | 16 / 4 / 0.05 | 0.96 plus or minus 0.05 |
| 5. Outer Jacket | FEP (Fluorinated Ethylene Propylene) | Not Applicable | 1.15 plus or minus 0.05 |
Electrical Performance Characteristics
| Performance Parameter | Technical Value |
| Characteristic Impedance (at 1ns) | 50 plus or minus 4 Ohm |
| Capacitance | 98 plus or minus 2 picofarads per meter |
| Propagation Velocity | 70 plus or minus 2 percent |
| Voltage Standing Wave Ratio (0 to 6 Gigahertz) | Less than or equal to 1.35 |
| Maximum Operating Voltage | 1000 Volts |
Signal Attenuation Reference Table (DC to 6 GHz)
| Frequency (Gigahertz) | Maximum Attenuation (Decibels per meter) |
| 1 GHz | Less than or equal to 1.88 dB per meter |
| 2 GHz | Less than or equal to 2.55 dB per meter |
| 3 GHz | Less than or equal to 3.05 dB per meter |
| 4 GHz | Less than or equal to 3.52 dB per meter |
| 5 GHz | Less than or equal to 4.05 dB per meter |
| 6 GHz | Less than or equal to 4.40 dB per meter |
Professional Industry Advantages
-
Advanced Multi-Shielding Architecture: This premium cable utilizes a unique dual-shielding design. The 100% coverage copper-plastic composite tape provides a total seal against high-frequency interference, while the high-density tinned copper braid offers robust mechanical protection and additional electromagnetic isolation.
-
Superior Signal Integrity: Specifically optimized for high-performance data transmission. With an exceptionally low attenuation rate (only 1.88 dB/m at 1 GHz) and stable 50 Ohm impedance, it ensures high-fidelity signal delivery even in dense electronic environments.
-
Premium Fluoropolymer Construction: Both the insulation and jacket are manufactured from high-grade FEP (Fluorinated Ethylene Propylene), ensuring the cable remains chemically inert, moisture-proof, and thermally stable across a wide spectrum from -55 degrees Celsius to +125 degrees Celsius.
-
Optimized Micro-miniature Profile: With an outside diameter of only 1.15 mm, this cable supports high-density integration in restricted spaces such as medical imaging gantries, robotic surgical arms, and compact electronic warfare modules.
-
Industry Compliance & Safety: Rated for 1000V operating voltage, this series provides a significant safety margin compared to standard signal cables, ensuring absolute reliability for mission-critical industrial and medical applications.