UL1911 PFA Insulated High Performance Specialty Wire 600V – BYC Cables

Product Overview

Feature Specification
Standard UL 1911
Insulation Material PFA (Perfluoroalkoxy)
Rated Voltage 1,000V to 50,000V DC (High-Voltage / Ignition Rated)
Temperature Range -100°C to +250°C (-148°F to +482°F)
Conductor Options Nickel-plated Copper, Silver-plated Copper, or Pure Nickel
Available Colors White, Blue, Red, Black, Brown, Yellow, Green, Transparent, Yellow/Green
Applications High-tension internal wiring for electronic ignition systems, high-voltage pulse circuits, and professional heating equipment.

Technical Parameter Table

Note: In the voltage columns below, values are presented as (Insulation Thickness / Finished Outside Diameter) in millimeters.

AWG (Gauge) Conductor Construction (No. x mm) Conductor Diameter (mm) 1,000V (Thick/Diameter) (mm) 10,000V (Thick/Diameter) (mm) 30,000V (Thick/Diameter) (mm) 50,000V (Thick/Diameter) (mm) Max Resistance @ 20°C (68°F) (Ohm/km)
24 7 x 0.16 / 19 x 0.10 0.48 / 0.6 0.4 / 1.41 0.8 / 2.21 1.0 / 2.61 1.5 / 3.61 85.9
22 7 x 0.20 / 19 x 0.12 0.76 0.4 / 1.56 0.8 / 2.26 1.0 / 2.76 1.5 / 3.76 54.3
20 7 x 0.25 / 19 x 0.15 0.95 / 0.96 0.4 / 1.75 0.8 / 2.55 1.0 / 2.95 1.5 / 3.95 34.6
18 7 x 0.32 / 19 x 0.19 1.19 / 1.18 0.4 / 1.99 0.8 / 2.79 1.0 / 3.19 1.5 / 4.19 21.8
16 7 x 0.40 / 19 x 0.23 1.53 / 1.51 0.4 / 2.33 0.8 / 3.13 1.0 / 3.53 1.5 / 4.53 13.5
14 7 x 0.50 1.86 0.4 / 2.66 0.8 / 3.46 1.0 / 3.86 1.5 / 4.86 8.45
12 19 x 0.30 2.32 0.5 / 3.32 0.9 / 4.12 1.1 / 4.52 1.8 / 5.92 5.31
10 19 x 0.37 3.02 0.6 / 4.22 1.0 / 5.02 1.2 / 5.42 2.0 / 7.02 3.343

Professional Industry Features

  • High Dielectric Integrity: The PFA insulation is specifically engineered to handle high-tension pulses and ignition discharges, preventing electrical leakage or jacket breakdown in critical systems.
  • Extreme Thermal Stability: This wire maintains its physical and electrical properties across a wide temperature spectrum, from deep cryogenic environments at -100°C (-148°F) to constant high-heat exposure at +250°C (+482°F).
  • Advanced Conductor Protection: By using Nickel-plated Copper or Silver-plated Copper, the conductor remains highly resistant to oxidation and corrosion, ensuring long-term reliability even in humid or chemically aggressive environments.
  • Chemical & Moisture Immunity: PFA is chemically inert and non-hygroscopic, making it the ideal choice for applications exposed to oils, fuels, and industrial solvents.
  • Optimized for Precision Ignition: Widely used as internal leads for high-voltage transformers and pulses in professional gas ignition modules and scientific instruments.

contact us

STEP 1

Inquiry Received

STEP 2

Technical Review

STEP 3

24H Response​