Product Overview
| Feature |
Specification |
| Standard |
UL 1911 |
| Insulation Material |
PFA (Perfluoroalkoxy) |
| Rated Voltage |
1,000V to 50,000V DC (High-Voltage / Ignition Rated) |
| Temperature Range |
-100°C to +250°C (-148°F to +482°F) |
| Conductor Options |
Nickel-plated Copper, Silver-plated Copper, or Pure Nickel |
| Available Colors |
White, Blue, Red, Black, Brown, Yellow, Green, Transparent, Yellow/Green |
| Applications |
High-tension internal wiring for electronic ignition systems, high-voltage pulse circuits, and professional heating equipment. |
Technical Parameter Table
Note: In the voltage columns below, values are presented as (Insulation Thickness / Finished Outside Diameter) in millimeters.
| AWG (Gauge) |
Conductor Construction (No. x mm) |
Conductor Diameter (mm) |
1,000V (Thick/Diameter) (mm) |
10,000V (Thick/Diameter) (mm) |
30,000V (Thick/Diameter) (mm) |
50,000V (Thick/Diameter) (mm) |
Max Resistance @ 20°C (68°F) (Ohm/km) |
| 24 |
7 x 0.16 / 19 x 0.10 |
0.48 / 0.6 |
0.4 / 1.41 |
0.8 / 2.21 |
1.0 / 2.61 |
1.5 / 3.61 |
85.9 |
| 22 |
7 x 0.20 / 19 x 0.12 |
0.76 |
0.4 / 1.56 |
0.8 / 2.26 |
1.0 / 2.76 |
1.5 / 3.76 |
54.3 |
| 20 |
7 x 0.25 / 19 x 0.15 |
0.95 / 0.96 |
0.4 / 1.75 |
0.8 / 2.55 |
1.0 / 2.95 |
1.5 / 3.95 |
34.6 |
| 18 |
7 x 0.32 / 19 x 0.19 |
1.19 / 1.18 |
0.4 / 1.99 |
0.8 / 2.79 |
1.0 / 3.19 |
1.5 / 4.19 |
21.8 |
| 16 |
7 x 0.40 / 19 x 0.23 |
1.53 / 1.51 |
0.4 / 2.33 |
0.8 / 3.13 |
1.0 / 3.53 |
1.5 / 4.53 |
13.5 |
| 14 |
7 x 0.50 |
1.86 |
0.4 / 2.66 |
0.8 / 3.46 |
1.0 / 3.86 |
1.5 / 4.86 |
8.45 |
| 12 |
19 x 0.30 |
2.32 |
0.5 / 3.32 |
0.9 / 4.12 |
1.1 / 4.52 |
1.8 / 5.92 |
5.31 |
| 10 |
19 x 0.37 |
3.02 |
0.6 / 4.22 |
1.0 / 5.02 |
1.2 / 5.42 |
2.0 / 7.02 |
3.343 |
Professional Industry Features
-
High Dielectric Integrity: The PFA insulation is specifically engineered to handle high-tension pulses and ignition discharges, preventing electrical leakage or jacket breakdown in critical systems.
-
Extreme Thermal Stability: This wire maintains its physical and electrical properties across a wide temperature spectrum, from deep cryogenic environments at -100°C (-148°F) to constant high-heat exposure at +250°C (+482°F).
-
Advanced Conductor Protection: By using Nickel-plated Copper or Silver-plated Copper, the conductor remains highly resistant to oxidation and corrosion, ensuring long-term reliability even in humid or chemically aggressive environments.
-
Chemical & Moisture Immunity: PFA is chemically inert and non-hygroscopic, making it the ideal choice for applications exposed to oils, fuels, and industrial solvents.
-
Optimized for Precision Ignition: Widely used as internal leads for high-voltage transformers and pulses in professional gas ignition modules and scientific instruments.